{"id":9855,"date":"2025-03-11T10:24:15","date_gmt":"2025-03-11T09:24:16","guid":{"rendered":"https:\/\/www.sicep.it\/?post_type=product&#038;p=9855"},"modified":"2026-01-20T16:20:15","modified_gmt":"2026-01-20T15:20:15","slug":"firelink-fl-8","status":"publish","type":"product","link":"https:\/\/www.sicep.it\/en\/producer\/firelink-fl-8\/","title":{"rendered":"Fire-Link FL-8"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"<p>The regulations governing fire-fighting systems foresee the need for a transmission system that can transfer fire, fault and out-of-service alarms to an alarm receiving centre in the event of a 24-hour failure, so that the personnel in charge can promptly follow up on intervention measures.<\/p>\n<p>The connection between the fire alarm system and the receiving stations must be constantly monitored and entrusted to an EN 54-21 compliant transmitter with dual communication vector, such as Fire-Link.<\/p>\n<p>All unmanned sites that are required to have a fire detection system must therefore have such a connection. With their own monitoring centres and the supervised connection of the Fire-Link, security companies can take over and manage these reports, guaranteeing maximum operational security.<\/p>\n<ul>\n<li>Bi-directional transmitter EN 54-21<\/li>\n<li>Communication in: Lan, 4G\/LTE, Sms and voice messages (TTS)<\/li>\n<li>8 inputs<\/li>\n<li>8 remote control outputs<\/li>\n<li>PSTN input for SIA and Contact-ID conversion<\/li>\n<li>MVS and SIA-IP DC09 protocol<\/li>\n<li>Encrypted transmission of information<\/li>\n<li>Adjustable transmission times (minimum polling time 90s)<\/li>\n<li>ALWAYS-ON connection (roaming SIM compatibility)<\/li>\n<li>Integrated anti-jamming system<\/li>\n<li>UF-L connector for external antenna<\/li>\n<li>Event history (max. 1024)<\/li>\n<li>Status LEDs for system controls and communication<\/li>\n<li>Integrated power supply and rechargeable backup battery<\/li>\n<li>Local or remote programming<\/li>\n<li>Full compatibility with MvsNET system, EN 50518 compliant<\/li>\n<li>Reduced footprint<\/li>\n<li>\u00a0Certifications\n<ul>\n<li>EN 54-21:2006 (CPR)<\/li>\n<li>EN 50131-10:2015<\/li>\n<li>EN 50136-1:2019<\/li>\n<li>EN 50136-2:2014<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><img loading=\"lazy\" class=\"alignleft wp-image-4712\" src=\"https:\/\/www.sicep.it\/wp-content\/uploads\/2020\/05\/4G-lte-ready.jpg\" alt=\"\" width=\"100\" height=\"100\" \/><\/p>\n","protected":false},"featured_media":9861,"template":"","meta":[],"product_cat":[121],"product_tag":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Fire-Link FL-8 - Sicep<\/title>\n<meta name=\"description\" content=\"Fire-Link FL-8 - Sicep - The connection between the fire alarm system and the receiving stations must be kept under control and entrusted to a transmitter conforming to EN 54-21.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.sicep.it\/en\/producer\/firelink-fl-8\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Fire-Link FL-8 - Sicep\" \/>\n<meta property=\"og:description\" content=\"Fire-Link FL-8 - Sicep - The connection between the fire alarm system and the receiving stations must be kept under control and entrusted to a transmitter conforming to EN 54-21.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sicep.it\/en\/producer\/firelink-fl-8\/\" \/>\n<meta property=\"og:site_name\" content=\"Sicep\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-20T15:20:15+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.sicep.it\/wp-content\/uploads\/2025\/03\/firelink-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"1200\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.sicep.it\/en\/producer\/firelink-fl-8\/\",\"url\":\"https:\/\/www.sicep.it\/en\/producer\/firelink-fl-8\/\",\"name\":\"Fire-Link FL-8 - Sicep\",\"isPartOf\":{\"@id\":\"https:\/\/www.sicep.it\/#website\"},\"datePublished\":\"2025-03-11T09:24:16+00:00\",\"dateModified\":\"2026-01-20T15:20:15+00:00\",\"description\":\"Fire-Link FL-8 - Sicep - The connection between the fire alarm system and the receiving stations must be kept under control and entrusted to a transmitter conforming to EN 54-21.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.sicep.it\/en\/producer\/firelink-fl-8\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.sicep.it\/en\/producer\/firelink-fl-8\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.sicep.it\/en\/producer\/firelink-fl-8\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.sicep.it\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Fire-Link FL-8\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.sicep.it\/#website\",\"url\":\"https:\/\/www.sicep.it\/\",\"name\":\"Sicep\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/www.sicep.it\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.sicep.it\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.sicep.it\/#organization\",\"name\":\"Sicep\",\"url\":\"https:\/\/www.sicep.it\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.sicep.it\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.sicep.it\/wp-content\/uploads\/2020\/06\/sicep.jpg\",\"contentUrl\":\"https:\/\/www.sicep.it\/wp-content\/uploads\/2020\/06\/sicep.jpg\",\"width\":512,\"height\":512,\"caption\":\"Sicep\"},\"image\":{\"@id\":\"https:\/\/www.sicep.it\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Fire-Link FL-8 - Sicep","description":"Fire-Link FL-8 - Sicep - The connection between the fire alarm system and the receiving stations must be kept under control and entrusted to a transmitter conforming to EN 54-21.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.sicep.it\/en\/producer\/firelink-fl-8\/","og_locale":"en_US","og_type":"article","og_title":"Fire-Link FL-8 - Sicep","og_description":"Fire-Link FL-8 - Sicep - The connection between the fire alarm system and the receiving stations must be kept under control and entrusted to a transmitter conforming to EN 54-21.","og_url":"https:\/\/www.sicep.it\/en\/producer\/firelink-fl-8\/","og_site_name":"Sicep","article_modified_time":"2026-01-20T15:20:15+00:00","og_image":[{"width":1200,"height":1200,"url":"https:\/\/www.sicep.it\/wp-content\/uploads\/2025\/03\/firelink-1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.sicep.it\/en\/producer\/firelink-fl-8\/","url":"https:\/\/www.sicep.it\/en\/producer\/firelink-fl-8\/","name":"Fire-Link FL-8 - Sicep","isPartOf":{"@id":"https:\/\/www.sicep.it\/#website"},"datePublished":"2025-03-11T09:24:16+00:00","dateModified":"2026-01-20T15:20:15+00:00","description":"Fire-Link FL-8 - Sicep - The connection between the fire alarm system and the receiving stations must be kept under control and entrusted to a transmitter conforming to EN 54-21.","breadcrumb":{"@id":"https:\/\/www.sicep.it\/en\/producer\/firelink-fl-8\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sicep.it\/en\/producer\/firelink-fl-8\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.sicep.it\/en\/producer\/firelink-fl-8\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.sicep.it\/en\/"},{"@type":"ListItem","position":2,"name":"Fire-Link FL-8"}]},{"@type":"WebSite","@id":"https:\/\/www.sicep.it\/#website","url":"https:\/\/www.sicep.it\/","name":"Sicep","description":"","publisher":{"@id":"https:\/\/www.sicep.it\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sicep.it\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.sicep.it\/#organization","name":"Sicep","url":"https:\/\/www.sicep.it\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.sicep.it\/#\/schema\/logo\/image\/","url":"https:\/\/www.sicep.it\/wp-content\/uploads\/2020\/06\/sicep.jpg","contentUrl":"https:\/\/www.sicep.it\/wp-content\/uploads\/2020\/06\/sicep.jpg","width":512,"height":512,"caption":"Sicep"},"image":{"@id":"https:\/\/www.sicep.it\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.sicep.it\/en\/wp-json\/wp\/v2\/product\/9855"}],"collection":[{"href":"https:\/\/www.sicep.it\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.sicep.it\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.sicep.it\/en\/wp-json\/wp\/v2\/media\/9861"}],"wp:attachment":[{"href":"https:\/\/www.sicep.it\/en\/wp-json\/wp\/v2\/media?parent=9855"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.sicep.it\/en\/wp-json\/wp\/v2\/product_cat?post=9855"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.sicep.it\/en\/wp-json\/wp\/v2\/product_tag?post=9855"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}